Home / Autodocs / input.device
NAME
- IND_SETPERIOD
-
Set the key repeat period
FUNCTION
This command sets the period at which a repeating key repeats.
This command always executes immediately.
INPUTS
It is a timerequest
- tr_node.io_Message
-
mn_ReplyPort set if quick I/O is not possible
- tr_node.io_Device
-
preset by the call to OpenDevice
- tr_node.io_Unit
-
preset by the call to OpenDevice
- tr_node.io_Command
-
IND_SETPERIOD
- tr_node.io_Flags
-
IOB_QUICK set if quick I/O is possible
- tr_time.tv_secs
-
the repeat period seconds
- tr_time.tv_micro
-
the repeat period microseconds